Our biggest advantages are the diversity of the tests and their applicability to various standards depending on customers' requests.

The following are our capabilities and skills grouped under 4 main categories:
  • Component check-up
  • Mechanical Laboratory
  • Calibration
  • Destructive/Non-destructive Check-up
These capabilities and skills are being employed in the qualification and serial production of Europe STINGER parts, in the qualification and lot acceptance tests of the 12 mm.MRAML launcher system , in the production of RAPIER guided missile parts, in the qualification , research and development and lot acceptance tests of the parts produced for the ATACMS project and in the equipment and component tests belonging to other industrial corporations.

COMPONENT CHECK-UP

Three-Dimensional Measurement Counters

  • DEA- Brown&Sharp IOTA 2025
  • DEA- Brown&Sharp Scirocco Record-MP
  • DEA- Brown&Sharp Global Image
30'' Profile Projection Stinger Wing Angle Control Unit

COMPANY CMM MODEL STROKES MEASURING
ACCURACY (µm)
MAX PART
WEIGHT (kg)
X
(mm)
Y
(mm)
Z
(mm)
Brown & Sharp
e - DEA
IOTA
DIAMOND
2205
2650 1025 1025 6 + 6L/1000 2500
Brown & Sharp
e - DEA
SCIROCCO
RECORD-MP
09.14.07
860 1400 660 1.9 + 0.75L/250 1800
Brown & Sharp
e - DEA
GLOBAL
IMAGE
12.15.10
1200 1500 1000 2,5 + L/333 1800


LABORATORIES

Environmental Conditions Laboratory

  • Heat Conditioning and Transformation,
  • Heat and Humidity Tests
  • Vibration Test
  • Salt Test (Corrosion)
  • Heat Shock Test
  • Stinger BCU Activation

Metallurgy Laboratory

  • Pull-Press Tests (0-250 KN)
  • Notch Stroke Test
  • Material Analyses
  • Hardness Tests (Rockwell, Brinell, Vickers)
  • Irritation Tests
  • Micro-hardness Measurements (Vickers)
  • Microstructure Analysis
  • Determination of Plate Thickness
  • Preparation of Hardness Sample
  • Infra Red Reflection Measurement
  • Dye Gloss Measurement
  • Electricity Conductivity Measurement

CALIBRATION
  • Compass
  • Micrometer
  • Elevation Measurement
  • Buffer Gauges

UN-DESTRUCTIVE CHECK-UP
  • Magnetic Particule Check-Up
  • Liquid Penetration Check-Up
  • Ultrasonic Check-Up







Quality Policy
Special Processes
Quality Capabilities
Quality Certificates
Six Sigma
© 2008 Kale Holding A.Ş.Site Creation & Technology by MagiClick Digital Solutions